# EMC, Mechanical, DFM, and DFT

Treat every external cable, connector, shield, and exposed conductor as an EMC/ESD boundary.

Place transient protection where energy enters. Give surge and ESD current a short low-inductance path to its intended return. Do not route discharge through sensitive logic by accident.

Keep common-mode conversion low by preserving pair symmetry and reference continuity.

Name the current path instead of arguing from labels such as analog ground or digital ground. A split plane is justified only when the complete signal and return topology supports it.

Mechanical review must verify connector mating direction and insertion envelope, mounting-hole keepouts, screw-head clearance, component height, board-edge clearance, heatsink/airflow space, cable bend/strain relief, and test/programming access after assembly.

Bind fabrication rules to the chosen fab: trace/space, copper, drill, annular ring, aspect ratio, solder mask, copper-to-edge, impedance service, controlled-depth operations, finish, material, and panel constraints. Do not silently rely on generic KiCad defaults.

Assembly review must cover package orientation, pin-1 evidence, polarized parts, courtyard conflicts, solderability, paste exceptions, fiducials, side restrictions, and rework access.

Expose test points for critical rails, reset, clock, boot straps, programming/debug, and important buses where practical.