# Power Integrity and Thermal

Power integrity begins with current loops, not capacitor count.

For each regulator trace the input current path, keep the high di/dt input loop compact, bound switch-node copper, place bootstrap/gate-drive parts by topology, protect the feedback sense path, close the output-current loop, and provide a credible thermal path.

For decoupling separate bulk-energy storage from local high-frequency charge. Account for capacitor mounting inductance, vias, planes, and package inductance. Printed capacitance alone does not prove useful impedance at frequency.

For planes and pours verify neck-downs at pads, vias, connectors, and thermal spokes; identify slots caused by keepouts and antipads; preserve return continuity; and check both DC drop and transient current paths.

For sensitive analog control where digital and switching currents return. Do not split ground reflexively. Placement, loop control, filtering, and current-path ownership matter more than labels.

Thermal claims require dissipation, package thermal path, copper geometry, ambient, airflow, and enclosure assumptions. Missing inputs mean thermal margin UNKNOWN.

Bench evidence should include rail voltage, ripple/noise with correct probing, startup sequencing, relevant load transient behavior, and regulator temperature under representative load.