{"_id":"node-red-contrib-schneider-powerlogic","_rev":"54-574c7e678cef44576d843b49c19fea73","name":"node-red-contrib-schneider-powerlogic","dist-tags":{"latest":"1.0.13"},"versions":{"1.0.12":{"name":"node-red-contrib-schneider-powerlogic","version":"1.0.12","description":"A Node-RED nodes to read Schneider PowerLogic series over Modbus TCP/IP.","author":{"name":"Nicolò Toscani"},"license":"MIT","node-red":{"nodes":{"pm3000":"pm3000.js","pm5000":"pm5000.js","iem300":"iem3000.js","powertag":"powertag.js","smartlink":"smartlink.js","converter":"converter.js"}},"main":"pm3000.js","scripts":{"test":"echo \"Error: no test specified\" && exit 1"},"keywords":["node-red","schneider","pm3000","pm5000","iem300","powertag","smartlink","energymeter","link150","powerlogic"],"homepage":"https://github.com/NicoloToscani/node-red-contrib-schneider-powerlogic#readme","repository":{"type":"git","url":"git+https://github.com/NicoloToscani/node-red-contrib-schneider-powerlogic.git"},"dependencies":{},"directories":{"doc":"docs"},"gitHead":"b88874e1e4e5698550b6edd431e406d763caad3b","bugs":{"url":"https://github.com/NicoloToscani/node-red-contrib-schneider-powerlogic/issues"},"_id":"node-red-contrib-schneider-powerlogic@1.0.12","_nodeVersion":"16.19.0","_npmVersion":"8.4.1","dist":{"integrity":"sha512-vywWOWojdUJnnnUys1CASJ5jLP48j0JcY4baZJn45RoqDNHBMlTZewlCGsl2/d1a7g2qgpoZ8bjRQv5UK8RAJg==","shasum":"bcc144bd442439e12f93e73f4c490bd03f9c20e7","tarball":"https://registry.npmjs.org/node-red-contrib-schneider-powerlogic/-/node-red-contrib-schneider-powerlogic-1.0.12.tgz","fileCount":20,"unpackedSize":485168,"signatures":[{"keyid":"SHA256:jl3bwswu80PjjokCgh0o2w5c2U4LhQAE57gj9cz1kzA","sig":"MEQCICT7rYonvMITwyocM1yMrdY3lKduSoIAKMsLRqxKptRVAiBEPEOYh15eYC12lnpFqGOJvZHtYwSfVsZ3X3/b2h2bHg=="}],"npm-signature":"-----BEGIN PGP SIGNATURE-----\r\nVersion: OpenPGP.js v4.10.10\r\nComment: https://openpgpjs.org\r\n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\r\n7dHho3SGkTuulHHq6rYQCmVFw7hoxQ//mzU=\r\n=CFsh\r\n-----END PGP SIGNATURE-----\r\n"},"_npmUser":{"name":"bigo90","email":"toscani.nicolo90@gmail.com"},"maintainers":[{"name":"bigo90","email":"toscani.nicolo90@gmail.com"}],"_npmOperationalInternal":{"host":"s3://npm-registry-packages","tmp":"tmp/node-red-contrib-schneider-powerlogic_1.0.12_1682492530323_0.16619545016129722"},"_hasShrinkwrap":false},"1.0.13":{"name":"node-red-contrib-schneider-powerlogic","version":"1.0.13","description":"A Node-RED nodes to read Schneider PowerLogic series over Modbus TCP/IP.","author":{"name":"Nicolò Toscani"},"license":"MIT","node-red":{"nodes":{"pm3000":"pm3000.js","pm5000":"pm5000.js","iem300":"iem3000.js","powertag":"powertag.js","smartlink":"smartlink.js","converter":"converter.js"}},"main":"pm3000.js","scripts":{"test":"echo \"Error: no test specified\" && exit 1"},"keywords":["node-red","schneider","pm3000","pm5000"],"homepage":"https://github.com/NicoloToscani/node-red-contrib-schneider-powerlogic#readme","repository":{"type":"git","url":"git+https://github.com/NicoloToscani/node-red-contrib-schneider-powerlogic.git"},"dependencies":{},"directories":{"doc":"docs"},"gitHead":"b88874e1e4e5698550b6edd431e406d763caad3b","bugs":{"url":"https://github.com/NicoloToscani/node-red-contrib-schneider-powerlogic/issues"},"_id":"node-red-contrib-schneider-powerlogic@1.0.13","_nodeVersion":"16.19.0","_npmVersion":"8.4.1","dist":{"integrity":"sha512-t7Np51Grq6wVDpNUNhGKeY2fHmXuA0Oqy2zyreGOOzFV3BbvvHTsKuKt5/9RBp2RnKV1Same3vr3x8QGVDW2KQ==","shasum":"0a991b262fc194eaa4faeb18871ed7cb057ab47e","tarball":"https://registry.npmjs.org/node-red-contrib-schneider-powerlogic/-/node-red-contrib-schneider-powerlogic-1.0.13.tgz","fileCount":20,"unpackedSize":468394,"signatures":[{"keyid":"SHA256:jl3bwswu80PjjokCgh0o2w5c2U4LhQAE57gj9cz1kzA","sig":"MEUCIGeY7EzsL9eARtP4uyOhC3piuOTaI8azCQMdW1vYDT7+AiEAofMfbzybR7fknd3DDLb439VoPgSLk2JJjYXf1IAkiDE="}]},"_npmUser":{"name":"bigo90","email":"toscani.nicolo90@gmail.com"},"maintainers":[{"name":"bigo90","email":"toscani.nicolo90@gmail.com"}],"_npmOperationalInternal":{"host":"s3://npm-registry-packages","tmp":"tmp/node-red-contrib-schneider-powerlogic_1.0.13_1683043417643_0.44790252587284574"},"_hasShrinkwrap":false}},"time":{"created":"2021-06-29T17:21:51.281Z","0.0.1":"2021-06-29T17:21:51.560Z","modified":"2023-05-02T16:03:38.003Z","0.0.2":"2021-06-29T17:41:48.929Z","0.0.3":"2021-07-01T06:17:42.607Z","0.0.4":"2021-07-01T16:31:02.000Z","0.0.5":"2021-07-01T16:41:56.123Z","0.0.6":"2022-04-14T13:03:51.188Z","0.0.7":"2022-04-14T13:12:19.190Z","0.0.8":"2022-04-14T13:15:26.215Z","0.0.9":"2022-04-14T14:10:05.616Z","0.0.10":"2022-04-14T17:58:51.001Z","0.0.11":"2022-10-15T17:57:48.558Z","0.0.12":"2022-10-17T08:33:47.929Z","0.0.13":"2022-10-17T15:12:45.959Z","0.0.14":"2022-10-17T15:30:30.288Z","1.0.0":"2022-11-08T07:26:08.570Z","1.0.1":"2022-11-08T07:30:59.350Z","1.0.2":"2022-11-08T08:41:35.808Z","1.0.3":"2022-11-08T16:38:18.066Z","1.0.4":"2022-11-09T08:16:47.334Z","1.0.5":"2022-11-09T08:44:31.994Z","1.0.6":"2022-11-09T08:53:19.915Z","1.0.7":"2022-11-10T08:10:31.580Z","1.0.8":"2022-11-10T08:12:54.488Z","1.0.9":"2022-11-10T08:40:41.601Z","1.0.10":"2022-11-17T13:46:22.458Z","1.0.11":"2022-12-22T08:41:36.187Z","1.0.12":"2023-04-26T07:02:10.527Z","1.0.13":"2023-05-02T16:03:37.875Z"},"maintainers":[{"name":"bigo90","email":"toscani.nicolo90@gmail.com"}],"description":"A Node-RED nodes to read Schneider PowerLogic series over Modbus TCP/IP.","homepage":"https://github.com/NicoloToscani/node-red-contrib-schneider-powerlogic#readme","keywords":["node-red","schneider","pm3000","pm5000"],"repository":{"type":"git","url":"git+https://github.com/NicoloToscani/node-red-contrib-schneider-powerlogic.git"},"author":{"name":"Nicolò Toscani"},"bugs":{"url":"https://github.com/NicoloToscani/node-red-contrib-schneider-powerlogic/issues"},"license":"MIT","readme":"# node-red-contrib-schneider-powerlogic\nA Node-RED nodes to read Schneider PowerLogic series over Modbus TCP/IP.\n## Node-RED configurator to read Schneider PowerLogic series over Modbus TCP/IP through Ethernet gateway\n\n## Install\nYou can install these nodes directly from the \"Manage Palette\" menu in the Node-RED interface.\n\nAlternatively, run the following command in your Node-RED user directory - typically `~/.node-red` on Linux or `%HOMEPATH%\\.nodered` on Windows\n\n        npm install node-red-contrib-schneider-powerlogic \n\n## How to use\n\n### meter node \nUse the `pm3000`, `pm5000`, `iem3000`, `powertag` or `smartlink` node to configure which information you want to request from the gateway.\n\nWire the output of the `pm3000`, `pm5000`, `iem3000`, `powertag` or `smartlink` to the input of the `Modbus Flex Getter` from 'node-red-contrib-modbus' modules.\n\nEnable check box `Keep Msg Properties` in the `Modbus Flex Getter` properties.\n\nWith `smartlink` node it's possible to send commands using `Modbus Flex Write` from 'node-red-contrib-modbus' modules.\n\n### converter node\nUse the `converter` node to prepare data for further use.\n\nWire the second output of the `Modbus Flex Getter` to the input of the `converter`.\n\n## Usage\n### Example flow\n```json\n[{\"id\":\"d2555447b94b0dcc\",\"type\":\"tab\",\"label\":\"Schneider PowerLogic \",\"disabled\":false,\"info\":\"\",\"env\":[]},{\"id\":\"86ce2a3dedddd570\",\"type\":\"debug\",\"z\":\"d2555447b94b0dcc\",\"name\":\"debug 1\",\"active\":true,\"tosidebar\":true,\"console\":false,\"tostatus\":false,\"complete\":\"false\",\"statusVal\":\"\",\"statusType\":\"auto\",\"x\":1860,\"y\":320,\"wires\":[]},{\"id\":\"2ea3581809c148b5\",\"type\":\"modbus-flex-getter\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"showStatusActivities\":false,\"showErrors\":false,\"logIOActivities\":false,\"server\":\"91f4dcc86c81af04\",\"useIOFile\":false,\"ioFile\":\"\",\"useIOForPayload\":false,\"emptyMsgOnFail\":false,\"keepMsgProperties\":true,\"x\":640,\"y\":520,\"wires\":[[],[\"72a042193c2a1199\"]]},{\"id\":\"e873507c1a4cc2aa\",\"type\":\"inject\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"props\":[{\"p\":\"payload\"},{\"p\":\"topic\",\"vt\":\"str\"}],\"repeat\":\"\",\"crontab\":\"\",\"once\":false,\"onceDelay\":0.1,\"topic\":\"\",\"payload\":\"\",\"payloadType\":\"date\",\"x\":220,\"y\":280,\"wires\":[[\"223f593a723a6bfa\"]]},{\"id\":\"eadc7e9ee8ac17ba\",\"type\":\"debug\",\"z\":\"d2555447b94b0dcc\",\"name\":\"iC60 commands\",\"active\":true,\"tosidebar\":true,\"console\":false,\"tostatus\":false,\"complete\":\"true\",\"targetType\":\"full\",\"statusVal\":\"\",\"statusType\":\"auto\",\"x\":860,\"y\":340,\"wires\":[]},{\"id\":\"c44731d4d5d7b18e\",\"type\":\"modbus-flex-write\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"showStatusActivities\":false,\"showErrors\":false,\"server\":\"91f4dcc86c81af04\",\"emptyMsgOnFail\":false,\"keepMsgProperties\":true,\"x\":630,\"y\":340,\"wires\":[[],[\"eadc7e9ee8ac17ba\"]]},{\"id\":\"223f593a723a6bfa\",\"type\":\"smartlink\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"unitId\":\"3\",\"mode\":\"write\",\"channel\":\"digital-channel-1\",\"device\":\"rca-ic60-ti24\",\"data\":\"open\",\"x\":400,\"y\":280,\"wires\":[[\"c44731d4d5d7b18e\"]]},{\"id\":\"beb5477ee95b5028\",\"type\":\"inject\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"props\":[{\"p\":\"payload\"},{\"p\":\"topic\",\"vt\":\"str\"}],\"repeat\":\"\",\"crontab\":\"\",\"once\":false,\"onceDelay\":0.1,\"topic\":\"\",\"payload\":\"\",\"payloadType\":\"date\",\"x\":220,\"y\":380,\"wires\":[[\"7aaccc524ec8845f\"]]},{\"id\":\"7aaccc524ec8845f\",\"type\":\"smartlink\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"unitId\":\"3\",\"mode\":\"write\",\"channel\":\"digital-channel-1\",\"device\":\"rca-ic60-ti24\",\"data\":\"close\",\"x\":400,\"y\":380,\"wires\":[[\"c44731d4d5d7b18e\"]]},{\"id\":\"adf54c6286982051\",\"type\":\"comment\",\"z\":\"d2555447b94b0dcc\",\"name\":\"Open iC60\",\"info\":\"\",\"x\":220,\"y\":240,\"wires\":[]},{\"id\":\"f36ba135ae795b60\",\"type\":\"comment\",\"z\":\"d2555447b94b0dcc\",\"name\":\"Close iC60\",\"info\":\"\",\"x\":220,\"y\":340,\"wires\":[]},{\"id\":\"d56956cbcd834295\",\"type\":\"pm3000\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"unitId\":\"1\",\"data\":\"frequency\",\"x\":400,\"y\":520,\"wires\":[[\"2ea3581809c148b5\"]]},{\"id\":\"1151f5b5a879a296\",\"type\":\"inject\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"props\":[{\"p\":\"payload\"},{\"p\":\"topic\",\"vt\":\"str\"}],\"repeat\":\"\",\"crontab\":\"\",\"once\":false,\"onceDelay\":0.1,\"topic\":\"\",\"payload\":\"\",\"payloadType\":\"date\",\"x\":220,\"y\":580,\"wires\":[[\"d56956cbcd834295\",\"2c83317f7f3b3eb1\",\"1fd213413562d295\"]]},{\"id\":\"72a042193c2a1199\",\"type\":\"converter\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"unitId\":\"\",\"data\":\"\",\"x\":860,\"y\":520,\"wires\":[[\"02297c1c19fdb5d3\"]]},{\"id\":\"02297c1c19fdb5d3\",\"type\":\"debug\",\"z\":\"d2555447b94b0dcc\",\"name\":\"PM3200 Frequency\",\"active\":true,\"tosidebar\":true,\"console\":false,\"tostatus\":false,\"complete\":\"true\",\"targetType\":\"full\",\"statusVal\":\"\",\"statusType\":\"auto\",\"x\":1060,\"y\":520,\"wires\":[]},{\"id\":\"1d395d3b376efb5f\",\"type\":\"modbus-flex-getter\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"showStatusActivities\":false,\"showErrors\":false,\"logIOActivities\":false,\"server\":\"91f4dcc86c81af04\",\"useIOFile\":false,\"ioFile\":\"\",\"useIOForPayload\":false,\"emptyMsgOnFail\":false,\"keepMsgProperties\":true,\"x\":640,\"y\":160,\"wires\":[[],[\"68f1ac817a330136\"]]},{\"id\":\"1e25713ce303215f\",\"type\":\"inject\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"props\":[{\"p\":\"payload\"},{\"p\":\"topic\",\"vt\":\"str\"}],\"repeat\":\"5\",\"crontab\":\"\",\"once\":false,\"onceDelay\":0.1,\"topic\":\"\",\"payload\":\"\",\"payloadType\":\"date\",\"x\":230,\"y\":160,\"wires\":[[\"9077db3bf532fcae\"]]},{\"id\":\"68f1ac817a330136\",\"type\":\"converter\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"unitId\":\"\",\"data\":\"\",\"x\":860,\"y\":160,\"wires\":[[\"3265dbba6e88d93c\"]]},{\"id\":\"3265dbba6e88d93c\",\"type\":\"debug\",\"z\":\"d2555447b94b0dcc\",\"name\":\"iC60 status \",\"active\":true,\"tosidebar\":true,\"console\":false,\"tostatus\":false,\"complete\":\"true\",\"targetType\":\"full\",\"statusVal\":\"\",\"statusType\":\"auto\",\"x\":1030,\"y\":160,\"wires\":[]},{\"id\":\"9077db3bf532fcae\",\"type\":\"smartlink\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"unitId\":\"3\",\"mode\":\"read\",\"channel\":\"digital-channel-1\",\"device\":\"rca-ic60-ti24\",\"data\":\"status\",\"x\":380,\"y\":160,\"wires\":[[\"1d395d3b376efb5f\"]]},{\"id\":\"d202649bd305b530\",\"type\":\"comment\",\"z\":\"d2555447b94b0dcc\",\"name\":\"Read iC60 status\",\"info\":\"\",\"x\":240,\"y\":120,\"wires\":[]},{\"id\":\"09a642ec4b385089\",\"type\":\"comment\",\"z\":\"d2555447b94b0dcc\",\"name\":\"Read PM3200\",\"info\":\"\",\"x\":210,\"y\":540,\"wires\":[]},{\"id\":\"ec890d91609eadc2\",\"type\":\"modbus-flex-getter\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"showStatusActivities\":false,\"showErrors\":false,\"logIOActivities\":false,\"server\":\"91f4dcc86c81af04\",\"useIOFile\":false,\"ioFile\":\"\",\"useIOForPayload\":false,\"emptyMsgOnFail\":false,\"keepMsgProperties\":true,\"x\":640,\"y\":580,\"wires\":[[],[\"55846acf464b4630\"]]},{\"id\":\"2c83317f7f3b3eb1\",\"type\":\"pm3000\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"unitId\":\"1\",\"data\":\"voltage-LL-Avg\",\"x\":400,\"y\":580,\"wires\":[[\"ec890d91609eadc2\"]]},{\"id\":\"55846acf464b4630\",\"type\":\"converter\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"unitId\":\"\",\"data\":\"\",\"x\":860,\"y\":580,\"wires\":[[\"e2d5346923febd25\"]]},{\"id\":\"e2d5346923febd25\",\"type\":\"debug\",\"z\":\"d2555447b94b0dcc\",\"name\":\"PM3200 L-L avg\",\"active\":true,\"tosidebar\":true,\"console\":false,\"tostatus\":false,\"complete\":\"true\",\"targetType\":\"full\",\"statusVal\":\"\",\"statusType\":\"auto\",\"x\":1050,\"y\":580,\"wires\":[]},{\"id\":\"30c1809ee14df422\",\"type\":\"modbus-flex-getter\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"showStatusActivities\":false,\"showErrors\":false,\"logIOActivities\":false,\"server\":\"91f4dcc86c81af04\",\"useIOFile\":false,\"ioFile\":\"\",\"useIOForPayload\":false,\"emptyMsgOnFail\":false,\"keepMsgProperties\":true,\"x\":640,\"y\":640,\"wires\":[[],[\"12d78170b9c6d098\"]]},{\"id\":\"1fd213413562d295\",\"type\":\"pm3000\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"unitId\":\"1\",\"data\":\"current-avg\",\"x\":400,\"y\":640,\"wires\":[[\"30c1809ee14df422\"]]},{\"id\":\"12d78170b9c6d098\",\"type\":\"converter\",\"z\":\"d2555447b94b0dcc\",\"name\":\"\",\"unitId\":\"\",\"data\":\"\",\"x\":860,\"y\":640,\"wires\":[[\"919d5d59075cd355\"]]},{\"id\":\"919d5d59075cd355\",\"type\":\"debug\",\"z\":\"d2555447b94b0dcc\",\"name\":\"PM3200 I-avg\",\"active\":true,\"tosidebar\":true,\"console\":false,\"tostatus\":false,\"complete\":\"true\",\"targetType\":\"full\",\"statusVal\":\"\",\"statusType\":\"auto\",\"x\":1040,\"y\":640,\"wires\":[]},{\"id\":\"91f4dcc86c81af04\",\"type\":\"modbus-client\",\"name\":\"PowertagLink\",\"clienttype\":\"tcp\",\"bufferCommands\":true,\"stateLogEnabled\":false,\"queueLogEnabled\":false,\"failureLogEnabled\":true,\"tcpHost\":\"192.168.100.50\",\"tcpPort\":\"502\",\"tcpType\":\"DEFAULT\",\"serialPort\":\"/dev/ttyUSB\",\"serialType\":\"RTU-BUFFERD\",\"serialBaudrate\":\"9600\",\"serialDatabits\":\"8\",\"serialStopbits\":\"1\",\"serialParity\":\"none\",\"serialConnectionDelay\":\"100\",\"serialAsciiResponseStartDelimiter\":\"0x3A\",\"unit_id\":\"1\",\"commandDelay\":\"1\",\"clientTimeout\":\"1000\",\"reconnectOnTimeout\":true,\"reconnectTimeout\":\"2000\",\"parallelUnitIdsAllowed\":true}]\n\n```\n\n## Meters data\n### PowerLogic series\nList of **PM3000/PM5000** meter data:\n\n| Measure                            | Units                 | Type          | \n| ---------------------------------- | --------------------- | ------------- | \n|  I1: phase 1 current               | A                     | Float32       | \n|  I2: phase 2 current               | A                     | Float32       |\n|  I3: phase 3 current               | A                     | Float32       |\n|  Current Avg                       | A                     | Float32       |\n|  Voltage L1-L2                     | V                     | Float32       |\n|  Voltage L2-L3                     | V                     | Float32       |\n|  Voltage L3-L1                     | V                     | Float32       |\n|  Voltage L-L Avg                   | V                     | Float32       |\n|  Voltage L1-N                      | V                     | Float32       |\n|  Voltage L2-N                      | V                     | Float32       |\n|  Voltage L3-N                      | V                     | Float32       |\n|  Voltage L-N Avg                   | V                     | Float32       |\n|  Active power phase 1              | kW                    | Float32       |\n|  Active power phase 2              | kW                    | Float32       |\n|  Active power phase 3              | kW                    | Float32       |\n|  Total active power                | kW                    | Float32       |\n|  Reactive power phase 1            | kVAR                  | Float32       |\n|  Reactive power phase 2            | kVAR                  | Float32       |\n|  Reactive power phase 3            | kVAR                  | Float32       |\n|  Total reactive power              | kVAR                  | Float32       |\n|  Apparent power phase 1            | kVA                   | Float32       |\n|  Apparent power phase 2            | kVA                   | Float32       |\n|  Apparent power phase 3            | kVA                   | Float32       |\n|  Total apparent power              | kVA                   | Float32       |\n|  Power factor phase 1              | -                     | Float32       |\n|  Power factor phase 2              | -                     | Float32       |\n|  Power factor phase 3              | -                     | Float32       |\n|  Power factor total                | -                     | Float32       |\n|  Load type (capacitive, inductive) | -                     | String        |\n|  Current unbalance I1              | %                     | Float32       |\n|  Current unbalance I2              | %                     | Float32       |\n|  Current unbalance I3              | %                     | Float32       |\n|  Current unbalance worst           | %                     | Float32       |\n|  Voltage unbalance L1-L2           | %                     | Float32       |\n|  Voltage unbalance L2-L3           | %                     | Float32       |\n|  Voltage unbalance L3-L1           | %                     | Float32       |\n|  Voltage unbalance L-L Worst       | %                     | Float32       |\n|  Voltage unbalance L1-N            | %                     | Float32       |\n|  Voltage unbalance L2-N            | %                     | Float32       |\n|  Voltage unbalance L3-N            | %                     | Float32       |\n|  Voltage unbalance L-N worst       | %                     | Float32       |\n|  Tangent phi total                 | -                     | Float32       |\n|  Frequency                         | Hz                    | Float32       |\n|  Temperature                       | °C                    | Float32       |\n|  Total active energy import        | Wh                    | Int64         |\n|  Total active energy export        | Wh                    | Int64         |\n|  Total reactive energy import      | VARh                  | Int64         |\n|  Total reactive energy export      | VARh                  | Int64         |\n|  Total apparent energy import      | VAh                   | Int64         |\n|  Total apparent energy export      | VAh                   | Int64         |\n|  Partial active energy import      | Wh                    | Int64         |\n|  Partial reactive energy import    | VARh                  | Int64         |\n|  Partial apparent energy import    | VAh                   | Int64         |\n|  Active energy import phase 1      | Wh                    | Int64         |\n|  Active energy import phase 2      | Wh                    | Int64         |\n|  Active energy import phase 3      | Wh                    | Int64         |\n|  Reactive energy import phase 1    | VARh                  | Int64         |\n|  Reactive energy import phase 2    | VARh                  | Int64         |\n|  Reactive energy import phase 3    | VARh                  | Int64         |\n|  Apparent energy import phase 1    | VAh                   | Int64         |\n|  Apparent energy import phase 2    | VAh                   | Int64         |\n|  Apparent energy import phase 3    | VAh                   | Int64         |\n|  Rate 1 active energy import       | Wh                    | Int64         |\n|  Rate 2 active energy import       | Wh                    | Int64         |\n|  Rate 3 active energy import       | Wh                    | Int64         |\n|  Rate 4 active energy import       | Wh                    | Int64         |\n\n\n### Meter data \n![data-config](docs/data-config.png)\n\n### Order data \n![control-config](docs/control-config.png)\n\n### Sample Measure flow\n![sample-flow](docs/sample-flow.png)\n\n### Sample Order flow\n![sample-order-flow](docs/sample-order-flow-ui.png)\n\n## Equipment compatibility\nCompare the values obtained with the measures on the installed device and report any bugs such as:\n+ measured value error\n+ measured value format\n+ unit of measure\n\nThese modules has been developed and tested on:\n+ PowerLogic PM3250\n+ Ethernet Gateway Link150\n\n\n\n\n","readmeFilename":"README.md"}